Learning Hub · Chapter 3 / 10
EU GDP chapter 3: Premises and equipment
Chapter 3 requires secure, clean storage areas with enough capacity, segregation for doubtful products, temperature control backed by mapping and monitoring, and equipment and computer systems that are qualified, calibrated and validated.
What the chapter requires
- 3.2Secure premises, access limited to authorised staff, and protection during receipt and dispatch.
- 3.2Falsified, expired, recalled and rejected products physically segregated at once in a dedicated area; products awaiting a decision segregated physically or by an equivalent electronic system.
- 3.2.1Temperature mapping of storage areas before use under representative conditions, and repeated after risk assessment or significant changes.
- 3.2.1Monitoring equipment placed according to the mapping, with records and alarms.
- 3.3Equipment calibrated and maintained; computerised systems validated before use.
- 3.3.2Qualification and validation of key equipment and processes, documented.
Section by section
Chapter 3 covers the physical side of GDP: buildings, storage conditions and the equipment and systems that keep medicines safe. It is where temperature mapping, alarms, segregation and computer system validation come from.
- 3.1 Principle
- 3.2 Premises
- 3.2.1 Temperature and environment control
- 3.3 Equipment
- 3.3.1 Computerised systems
- 3.3.2 Qualification and validation
3.1 Principle
Wholesale distributors need suitable and adequate premises, installations and equipment to store and distribute medicines properly. Storage areas should be clean, dry and kept within acceptable temperature limits.
3.2 Premises
Premises should be designed or adapted to keep the required storage conditions. They should be secure, structurally sound and big enough for safe storage and handling, with enough light to work accurately and safely. Where the wholesaler does not operate the premises directly, a contract should be in place, and those premises should be covered by a wholesale distribution authorisation.
Medicines are stored in segregated areas, clearly marked and accessible only to authorised staff. Any system replacing physical segregation, such as electronic segregation in a computerised system, should give equivalent security and be validated.
Products awaiting a decision on their disposition, or removed from saleable stock, should be segregated physically or through an equivalent electronic system; this includes, for example, products suspected of being falsified and returned products. Products from a third country that are not intended for the EU market should be physically segregated. Falsified, expired, recalled and rejected products should be immediately physically segregated and stored in a dedicated area away from all other medicines, with an appropriate degree of security and clear identification.
Products under special national rules, such as narcotics and psychotropics, may need special storage conditions and authorisations. Radioactive and other hazardous products, and products with fire or explosion risks, are stored in dedicated areas that meet local law and safety measures.
Receiving and dispatch bays should protect products from the weather and be separated from storage areas, with procedures to control goods in and out. Deliveries are examined in a designated, suitably equipped area. Unauthorised access is prevented, typically with a monitored intruder alarm and access control, and visitors are accompanied.
Premises are kept clean and free of litter and dust, with cleaning programmes, instructions and records. Cleaning equipment and agents must not become a source of contamination. A preventive pest control programme protects against insects, rodents and other animals. Rest, washing and refreshment rooms are separate from storage areas, and food, drink, smoking materials and personal medicines are not allowed in storage areas.
3.2.1 Temperature and environment control
Suitable equipment and procedures should be in place to check the environment in which medicines are stored, considering temperature, light, humidity and cleanliness.
An initial temperature mapping exercise is carried out on the storage area before use, under representative conditions. Temperature monitoring equipment is placed according to the mapping results, so that monitoring devices sit in the areas with the greatest fluctuations. The mapping is repeated according to a risk assessment, or whenever significant changes are made to the facility or the temperature control equipment. For small premises of a few square metres at room temperature, a risk assessment of potential influences, such as heaters, should be carried out and monitors placed accordingly.
3.3 Equipment
All equipment that affects storage and distribution is designed, located and maintained to a standard that suits its purpose, with planned maintenance for key equipment. Equipment used to control or monitor the storage environment is calibrated at defined intervals based on a risk and reliability assessment, and calibration is traceable to a national or international measurement standard.
Alarm systems should warn when storage conditions move outside the set limits, with alarm levels set appropriately and alarms tested regularly. Repair, maintenance and calibration must not compromise the integrity of the medicines. Records of repair, maintenance and calibration of key equipment, such as cold stores, alarm and access systems, refrigerators, temperature recorders and air handling units, are kept and the results retained.
3.3.1 Computerised systems
Before a computerised system is used, validation or verification studies should show that it achieves the intended results accurately, consistently and reproducibly. A detailed written description of the system, with diagrams where useful, is kept up to date, covering its principles, objectives, security measures, scope, main features, how it is used and how it interacts with other systems.
Only authorised people enter or change data. Data is protected physically or electronically against accidental or unauthorised changes, checked periodically for accessibility, and backed up at regular intervals. Back-up data is kept for the period set by national law, and at least five years, at a separate and secure location. Procedures describe what to do if the system fails, including how data is restored.
3.3.2 Qualification and validation
Wholesale distributors identify which key equipment qualification and which process validation they need to show correct installation and operation. The scope and extent, for example for storage or pick and pack processes, is decided through a documented risk assessment.
Equipment and processes are qualified or validated before first use and after any significant change, such as a repair or maintenance. Validation and qualification reports summarise the results and comment on any deviations. Deviations are documented and CAPA decided. Evidence of satisfactory validation and acceptance is produced and approved by appropriate personnel.
This page explains the guideline in plain language. It is not the legal text: read the official EU GDP Guidelines (2013/C 343/01) on EUR-Lex.
What it looks like in practice
- A mapping report that explains why probes sit where they do.
- An alarm test record and a call-out list that works at weekends.
- A validated stock system with a clear status for quarantine and rejected stock.
Questions
How often must temperature mapping be repeated?
The guidelines set no fixed interval. Mapping is repeated according to a risk assessment, or whenever the facility or temperature control equipment changes significantly (section 3.2.1).
Is electronic segregation allowed under GDP?
For products awaiting a decision, yes, if it gives equivalent security and is validated. Falsified, expired, recalled and rejected products must be physically segregated in a dedicated area, as must third-country products not intended for the EU market.
How long must back-up data be kept?
For the period set by national law, and at least five years, at a separate and secure location (section 3.3.1).
Which equipment must be calibrated?
Equipment used to control or monitor the storage environment, at intervals based on a risk and reliability assessment, traceable to a national or international standard (section 3.3).
Who this matters to most
Test yourself
Free GDP knowledge check
Thirteen practical questions on the EU GDP Guidelines, with explanations. Five minutes, no sign-up.
Take the free knowledge checkGDP Essentials
The whole EU GDP Guidelines in twelve short, narrated chapters. For everyone who handles, stores, moves or sells medicines.